| INCA | funded by the European Community
through the Fifth Framework Programme |
![]() |
| Nd: YAG-laser, pulse energy | about 300 mJ at 355 and 532 nm |
| Pulse repetition frequency | 30 Hz |
| Telescope | 1.1 m diam. primary mirror, 3.5 m focal length |
| Signal detection | 10 channel polychromator |
| photon counting / analog mode detection | |
| Installation | 20-feet-container, air conditioned |
| Power consumption | 380 V, 3 phase, 15 kW |
| Total weight | about 10 metric tons. |
| Instrument | Measurement | Range | Inlet |
| PMS-PCASP | Aerosol size distribution | 0.12-3.5 mm | Wing mount |
| PMS-FSSP-300 | Aerosol/Crytal size distribution | 0.3-30 mm | Wing mount |
| PMS-2DC | Crystal size distribution | 50-800 mm | Wing mount |
| Polar nephelometer | Scattering phase function | 1-500 mm | Wing mount |
| Hygrometer | Cloud water content | 0.002-1 g/kg | CVI probe |
| Instrument | Measurement | Range | Inlet |
| CPC 1 | Aerosol number density | D>10 nm | Aerosol probe |
| CPC 2 | Aerosol number density | D>15 nm | Aerosol probe |
| DMPS | Aerosol size distribution | 0.02-0.15 mm | Aerosol probe |
| PMS-PCASP | Aerosol size distribution | 0.12-3.5 mm | Aerosol probe |
| Filter samples | Particle composition | D>0.2 mm | Aerosol probe |
| Volatility | Thermal properties of particles | 0.02-2 mm | Aerosol probe |
| Black carbon | Differential absorption | >0.1 g m-3 | Aerosol probe |
| Instrument | Measurement | Range | Inlet |
| CPC 1 | Residual number density | D>10 nm | CVI probe |
| CPC 2 | Residual number density | D>15 nm | CVI probe |
| DMPS | Residual number density | 0.02-0.15 mm | CVI probe |
| PMS-PCASP | Residual number density | 0.12-3.5 mm | CVI probe |
| Filter samples | Residual particle composition | D>0.2 mm | CVI probe |
| Volatility | Thermal properties of residual particles | 0.02-2 mm | CVI probe |
| Black carbon | Differential absorption | >0.1 g m-3 | CVI probe |
| Instrument | Measurement | Range | Inlet |
| Hygrometer | Water vapour mixing ratios | 3-5000 ppm | Gas inlet |
| NO | Nitrogen oxide mixing ratio | 0.005-25 ppb | Gas inlet |
| NOy | Total reactive nitrogen gases | 0.05-25 ppb | Gas inlet |
| Ozone monitor | Stratospheric tracer | 10-1500 ppb | Gas inlet |
| Carbon monoxide | Tropospheric tracer | 5-500 ppb | Gas inlet |